Eltako ESR12Z-4DX-UC electronic impulse relay 4 x 1NO 16A / 8-230VACDC

Eltako ESR12Z-4DX-UC electronic impulse relay 4 x 1NO 16A / 8-230VACDC
Switching characteristics
Contacts 4 x 1NO
Control voltage 8-253VAC / 10-230VDC
Current 16A
All ON / all OFF Yes
Eltako ESR12Z-4DX-UC electronic impulse relay 4 x 1NO 16A / 8-230VACDC
€76.76
Ex Tax: €63.44
  • Ready to ship: 3-5 working days
  • Brand: Eltako
  • Model: ELTAKO-ESR12Z4DXUC
Fast Shipping
15+ Years Experience
Secure Payments
  • Universal control voltage 8-253VAC / 10-230VDC
  • With 4 independent contacts, 1NO contact each potential free 16 A/250 V AC
  • Can be used as 4 individual one-pole circuits (1NO+1NO+1NO+1NO)
  • Use as switching relay or as an impulse switch
  • Incandescent lamp load up to 2000 W
  • fluorescent lamps with conventional ballast or non compensated: 1000VA
  • fluorescent lamps with electronic ballast or compensated: 500VA
  • energy saving lamps or fluorescent lamps with electronic ballast: inrush current <70A 10ms
  • LED: 200W
  • Standby loss 0.03–0.4 watt only
  • Modular devices for DIN-EN 60715 TH35 rail mounting. 2 modules = 36 mm wide, 58 mm deep
  • Patented Eltako Duplex technology (DX) allows you to switch 3 of the 4 normally potential free contacts in zero passage switching when 230 V A/C voltage 50 Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and the phase conductors to 1 (L), 3 (L) or 5 (L). This results in an additional standby consumption of only 0.1 watt. If the channels are used to control switchgear that has no zero passage switching, (N) should not be connected, otherwise the additional off-delay would have the opposite effect
  • Local universal control voltage 8 to 230 V UC. In addition universal control inputs central ON and central OFF for 8 to 230V UC, electrically isolated from the local inputs
  • With additional group control inputs ON and OFF for 8..230 V UC. Same potential like the local control inputs. Groups of these impulse switches can be controlled separately using the group control inputs
  • Supply voltage same as the local control voltage
  • By using a bistable relay coil power loss and heating is avoided even in the on mode
  • The switched consumers may not be connected to the mains before the short automatic synchronisation after installation has terminated. Central commands always have priority, local control inputs are blocked as long as central commands are activated. In case of a power failure the system is disconnected in a defined mode.